Stuart Willis was very professional, friendly, and knowledgeable. He provided us with not so great news but gave us options to fix our AC. Would definitely recommend him.
Anthony and Arthur got the job done in one and a half days. They were hardworking, friendly and very polite and helpful. Highly recommend. Thank you 😃
The guys done excellent work, clean job and very professional and I’m very happy with the experience
Technician came and thoroughly cleaned our split unit. Nice work!
Josh and his team installed a new system in my home and were very professional and straight forward. They had the job complete in a days work and made sure it was finished the right way. Would recommend to anyone looking for hvac work.
Collin did an excellent job installing and explaining our new system. I highly recommend Total Air.
Excellent service from the quote, to the office staff. Installers were professional and thorough.
Excellent service combined with their own knowledge and customer courtesy. Thank you for an excellent representative.
SEND AN ADVISOR ON MONDAY AT 11 AM The condenser coil is badly damaged, the system is 22 years old
Capacitor was bad 40/5 System running and operating at this time
the mini split was cleaned That blower motor makes a small sound that it already made before being cleaned
Customer complained that unit is not cooling. Checked the unit and found out that capacitor was bad . Replaced capacitor and checked Freon levels and the Freon level was low. Checked with a leak detector to see where is leaking from but couldn’t find the leak. Need to add dye pack on the unit. Unit is 10 years old and recommend for replacment. Customer want to speak with a comfort advisor on Monday
Compressor not running. Hearing it try to start but not starting. Motor windings open. Hosed compressor down to try to cool but still not starting. Told her cost to change compressor and she said she cant do that. Suggested having a comfort advisor come out and she declined
Total Air Cares Membership w/ Additional System Performed maintenance on two split systems. Cleared both drain lines tested both float switches. Checked refrigerant pressures and temperature differentials. Checked amp draws on compressors fans and blowers. Checked condition of coils and blower assemblies. Units running, and cooling at this time. Highly recommend adding a UV system to keep bacteria from growing and mechanical parts, clean in the air handlers as well as adding surge protection for the outside units
IFlow System added to the system
Completed for maintenance on split system unit Tested refrigerant levels, and temperature Checked all wiring and components Tested capacitor capacitor was reading low. I replaced with a new capacitor. Tested fan and compressor amps Hosed off condenser coils Tested float switch Tested water pump UV bulb has gone bad but it is an older UV light. Customer must buy a new one if he wants replaced or replace himself. Took temperature splits from supply and return Unit is up and operating at this time
Blower Motor / Contactor Coils and evaporator is iced up completely and wires from motor are buried in ice. Need to let ice thaw in order to complete repair. Put bin in return box for water dripping Removed old motor and contacter. Installed new blower motor and contacter and required everything. Tested unit and blower motor is shutting off properly.
The drain was unclogged with drain solve and nitrogen.
Checked all major components on 2 units: Freon levels compressor , fan motor , capacitor, coils , flushed drain line , checked filters. The main unit is operating as designed. On the minisplit noticed that condenser coil is very dirty and need to be cleaned with chemicals
Capacitor was bad 35/5 Vacuumed and flushed condensate drain
We’re arrival the breaker was dripped. Start chicken the wires I ome the compressor and found out the compressor is short to ground compressor need to be your place. Customer wanted a code for replacing the compressor.
Arrived to find unit not running and the float switch being tripped. Cleared drain line and float switch and got the unit running. Highly recommend adding an eye flow device to prevent future drain line issues. Condenser coil is quite dirty highly recommend having it cleaned. Also highly recommend signing up for maintenance program to keep your unit maintained and prevent future issues from arising. This will also give a 20% discount on any of the work that needs to be performed.